Zurueck zur Suche

Reporte zur Charge U029559

Verknuepft ueber VAERS_ID mit VAERSDATA, Vax und Symptoms

4Reporte angezeigt
0Todesfaelle
0Hospitalisiert
0Lebensbedrohlich
0Bleibende Schaeden
CA 2 IN 1 NY 1

VAERS 2453477

MERCK & CO. INC. · PNEUMO (VAXNEUVANCE) · Charge u029559

moderat
Staat
IN
Alter
63,0
Geschlecht
M
Eingang
21.09.2022
Impfdatum
10.08.2022
Beginn
17.08.2022
Tage bis Beginn
7,0
Dosis
UNK
Route/Site
IM / LA
Tod: unbekannt Lebensbedrohlich: unbekannt Hospital: unbekannt Disable: unbekannt ER: unbekannt Erholt: nein
Hypoaesthesia Pain in extremity Paraesthesia

Symptomtext

Patient complained of soreness in L arm. Patient said both arms and hands feel numb and tingle like pins and needles. Patient vital signs 142/84, O2 97% on RA, Pulse 61, R- 20.

Weitere VAERSDATA-Felder
Praegender Schweregrund
Paraesthesia
Hospital-Tage
-
Labordaten
-
Aktuelle Erkrankungen
None
Vorgeschichte
Diabetes
Andere Medikamente
Simvastatin Novolog Creon Lisinopril Plavix Gabapentin Albuterol Spiriva Vitamin A Vitamin D Fish oil
Allergien
Aspirin
Vorherige Impfungen
-

VAERS 2535060

MERCK & CO. INC. · PNEUMO (VAXNEUVANCE) · Charge U029559

gering
Staat
NY
Alter
63,0
Geschlecht
F
Eingang
16.12.2022
Impfdatum
17.11.2022
Beginn
17.11.2022
Tage bis Beginn
0,0
Dosis
UNK
Route/Site
- / -
Tod: unbekannt Lebensbedrohlich: unbekannt Hospital: unbekannt Disable: unbekannt ER: unbekannt Erholt: nein
Expired product administered No adverse event

Symptomtext

No additional AE reported; patient was administered an expired dose of VAXNEUVANCE; This spontaneous report was received from a nurse via Pfizer referring to a 63 years old female patient. The patient's medical history, concurrent conditions, concomitant therapies, drug reactions and allergies were not reported. On 17-NOV-2022, the patient was vaccinated with pneumococcal 15v conj vaccine (crm197) (VAXNEUVANCE) injection, 0.5 milliliter, lot #U029559 (also reported as package batch #), expiration date: 16-NOV-2022, administered for prophylaxis (strength, and route of administration were not provided; fill batch 0001335181 had an assigned expiry of 21-NOV-2023, inconsistent information) (expired product administered). No additional adverse event (AE) was reported (no adverse event).

Weitere VAERSDATA-Felder
Praegender Schweregrund
Expired product administered
Hospital-Tage
-
Labordaten
-
Aktuelle Erkrankungen
-
Vorgeschichte
-
Andere Medikamente
-
Allergien
-
Vorherige Impfungen
-

VAERS 2292227

MERCK & CO. INC. · PNEUMO (VAXNEUVANCE) · Charge U029559

gering
Staat
CA
Alter
-
Geschlecht
U
Eingang
24.05.2022
Impfdatum
-
Beginn
-
Tage bis Beginn
-
Dosis
UNK
Route/Site
- / -
Tod: unbekannt Lebensbedrohlich: unbekannt Hospital: unbekannt Disable: unbekannt ER: unbekannt Erholt: nein
Device issue Syringe issue

Symptomtext

Sterile Injectable;Broken;Syringe Hub Defect; no adverse event; Field employee called to report a PQC in behalf of a medical assistant. The medical assistant told the field employee that 2 prefill pneumococcal 15v conj vaccine (CRM197) (VAXNEUVANCE) syringes were "sheared off" at the tip of the syringe where Luer Lock meets the body of the syringe. They were broken off while needles were being attached. Both syringes were from the same lot but she was not sure if they were from the same tray. Both of the broken syringes were discarded so no products can be returned to Merck. Please see attachments for the photos. No AE. No further information was available. QUESTION SECTION: Medium Risk: Broken Syringe Barrel High Risk: Cracked or Broken Luer Lock (Needle Attachment Issues), Broken Finger Flange. Notes: o A cracked syringe has a line or chip in the glass, but the syringe is essentially intact in one piece. A syringe is considered broken when the syringe is in 2 or more pieces. o A syringe is also considered "cracked" if it appears to be intact with evidence of a chip or crack OR appears to be intact initially but then breaks into 2 or more pieces during use (such as while attaching a needle or injecting diluent). o Please provide a detailed description of the defect using the questions below: o Is there a crack? UNSPECIFIED o If yes, describe the size, shape & depth of the crack: o Provide the exact location of the crack on the syringe: o Is the syringe broken into 2 or more pieces? YES o If yes, describe in detail how it is broken: (e.g. shattered, broken in half etc.) IT WAS SHEARED OFF. o Provide the exact location of the breakage on the syringe? BETWEEN THE BARREL AND LUER LOCK. o Does the syringe have a broken component? YES (e.g. broken syringe tip; loose or detached luer lock, or broken finger flange) o If yes, describe in detail how it is broken. o Provide the exact location of the breakage on the syringe? BETWEEN THE BARREL AND LUER LOCK. o Is the tip of the syringe or Luer lock adaptor loose or broken off of the syringe tip? YES (if yes describe) BROKEN OFF OF THE SYRINGE TIP o Was there difficulty trying to attach the syringe needle to the syringe? NO o If yes, describe o If yes, was it supplied by MERCK: YES/NO/NA/UNSPECIFIED o If not supplied by MERCK, what type & brand, needle size & gauge was used?' o Under what situation was this defect noticed: (select one) o While the syringe was still in the tray? YES/NO/NA/UNSPECIFIED o If yes, is there product (liquid or dried residue) in the tray? YES/NO/NA/UNSPECIFIED o Is there any broken glass or other separated component in the tray? (if yes specify) o After removing the syringe from the tray? YES/NO/NA/UNSPECIFIED o While trying to attach the needle to the syringe? YES o While giving the injection? YES/NO/NA/UNSPECIFIED o Immediately after giving the injection? YES/NO/NA/UNSPECIFIED o Was the syringe tip cap attached properly prior to use? UNSPECIFIED o If no, describe issue: o Was the syringe tray intact and undamaged on receipt? YES o If no, describe damage. o If the product came with a cellophane cover, was the cellophane covering the syringe tray intact and completely sealed? *See below. UNSPECIFIED o If no, describe damage o Was the syringe carton damaged prior to use? (i.e. crushed, ripped, unglued) UNSPECIFIED o If yes, describe o Was the product administered or exposed to patient's bodily fluids (i.e. biohazardous)? NO o If complaint sample is not/cannot be returned, please provide reason: CANNOT BE RETURNED BECAUSE THEY WERE DISCARDED. *If photos are available, ask the customer to send them. Retrieval Information: o Obtain product (& tray if possible) o Expedite return for cracked syringes. If there is a doubt whether it is cracked or broken, please expedite. NOTE: Vaccine Prefilled Syringes may be returned even if biohazardous. Sample Tracking Number: User's Experience: Repeat User Insertion Difficulty: Insertion Difficulty Details: Doubt About Presence: Doubt Details: Migration: Migration Details: Removal Problem: Removal Problem Details: 11-MAY-2022 19:30 PM :Attachment added to Service Cloud. 11-MAY-2022 19:30 PM :Attachment added to Service Cloud. 11-MAY-2022 19:30 PM :Attachment added to Service Cloud. 11-MAY-2022 19:30 PM :Attachment added to Service Cloud. 11-MAY-2022 19:30 PM :Attachment added to Service Cloud. 12-MAY-2022: Received & Attached photos. 12-MAY-2022; Second person reviewed 12-MAY-2022: Procode field updated to reflect upon confirmation.

Weitere VAERSDATA-Felder
Praegender Schweregrund
Device issue
Hospital-Tage
-
Labordaten
-
Aktuelle Erkrankungen
-
Vorgeschichte
-
Andere Medikamente
-
Allergien
-
Vorherige Impfungen
-

VAERS 2284646

MERCK & CO. INC. · PNEUMO (VAXNEUVANCE) · Charge U029559

gering
Staat
CA
Alter
-
Geschlecht
U
Eingang
03.05.2022
Impfdatum
10.05.2022
Beginn
10.05.2022
Tage bis Beginn
0,0
Dosis
UNK
Route/Site
IM / -
Tod: unbekannt Lebensbedrohlich: unbekannt Hospital: unbekannt Disable: unbekannt ER: unbekannt Erholt: unbekannt
Syringe issue

Symptomtext

On 5/10/22 an MA was attaching a needle to a Vaxneuvance vaccine when the end of the syringe sheered off and was stuck in the hub of the needle. Th item was Vaxeneuvance vaccine Lot number: U029559 NDC number: 0006-4329-01 EXP: 11/16/22 . Item was disposed of, see attached pictures.